Heat-Timer - ZCP 5 Zone Control Panel 926577-00
|
Please check for availability
Item Number: 46922
Manufacturer Name: Heat-Timer
Manufacturer Part No: 926577-00
|
|
ZCP Zone Control Panel (Zone
Switching Relay) Application 926577-00
Product Manuals and Downloads:
ZCP Product Manual
ZCP Sale Sheet
A Five-Zone Control that can operate
either Zone Pumps or Zone Valves. Supply
houses can stock only one zone switching relay control. As the same ZCP zone
control can be configured to operate either zone pumps or zone valves with end
switches.
Domestic Hot Water Zone. The first zone can be configured either as a heating
zone or a Domestic Hot Water (DHW) zone. The domestic hot water zone can then
be configured to either have priority or to run without priority. When Priority
is selected, an adjustable Priority Time Delay is provided for better control.
Secondary Hard to Heat Priority Zone. Even with Domestic Hot Water Priority set, this zone
switching relay can have a zone configured to be excluded from the priority.
This is helpful for hard to heat zones. The ZCP will provide heat to those
zones even during DHW priority calls.
Digital Display of All Zones Status. The ZCP is equipped with a two line digital display.
It displays all menu items in simple English. In addition, all zone status will
be displayed.
Expandable to 10 Zones. Although, a single ZCP zone switching relay can
control five zones, two zone switching relays can be daisy chained to offer a
total of up to ten zones. One will act as the master while the other will be
the Slave/Extension. Just purchase the extension cable.
Interface with the Outdoor Reset
Controls. The ZCP can be wired to
control the boiler and the system pump. Additionally, it can be wired to any
outdoor reset control as the HWE-SS,
HWE-MOV,
or VSP
to take advantage of its Outdoor Reset and Domestic Hot Water Set Point
capabilities.
Boiler Warm Up Period. To help reduce the effect of circulating cold water
to the zones when the boiler has not run for an hour, a call for any of the
zones will energize the Boiler and System Pump relays. However, all zone
outputs will be energized after the boiler warm up period.
Pump Delay. An adjustable Run-On delay is provided to help
dissipate the excess heat from the system in to the zones.
Features
- The ZCP has five built-in zone outputs in addition to boiler and
system pump outputs.
- Ease of zone output wiring. Connect you zone outputs power source
to one location on the ZCP. The ZCP will then power the zone pumps or zone
valves.
- Compare the ZCP to other market expandable switching relays.
- Ease of thermostat input wiring. If your thermostat requires 24vac
powering, just connect the transformer to the ZCP 24VAc input. The ZCP
will then provide power to the thermostat inputs.
- Add additional zones using another ZCP. Up to two ZCPs can be daisy
chained for a total of 10 zone control.
- Remote Enable/Disable (On/Off). Configure the On/Off input
terminals to act as a thermostat call or connect it to a an outdoor reset
control like the HWE-SS.
|
MSRP: $15.00
Price: $14.63
You Save: $0.37 (2 %)
ZCP Heat-Timer 018017-00 Mini Extension Cable
|
Price: From $704.40 to $1,263.91
Includes: Stainless Steel Valve Body & Motor Only
|
Price: From $847.46 to $1,822.50
Includes: Stainless Steel Valve Body, Control Module, & Sensor
|
Product Reviews
|
With a Customer Service Rep Monday thru Friday 8:00am-4:30pm EST
.
|
|