Laars JVH 75 Mini-Therm Induced Draft Gas-Fired Hydronic Boiler
Item Number: 10042
Manufacturer Name: Laars Heating Systems Company
Manufacturer Part No: JVH075
|
|
Specifications:
- Input (BTU/h): 75,000
- Input (kW): 21.9
- Firing Mode: On/Off
- Configuration: Hot Surface Pilot Ignition
- Heat Capacity (BTU/h): 62,300
- Heat Capacity (kW): 18.4
- Net IBR (BTU/h): 54,200
- AFUE: 83.2
- Minimum Clearances from Combustible Surfaces:
- Left Side: 2"
- Right Side: 5"
- Rear: 2"
- Front: 4"
- Flue: 6"
- Top: 23"
Standard Features:
- Design certified and tested by American and Canadian Gas Associations
- Maximum working pressure - water 30 psi, ASME rated
- Hydrostatic test pressure at factory - 60 psi
- Material specifications as per Section IV, ASME Code
- Designed and certified for placement on combustible floor (except carpeting)
- Maximum gas supply pressure - Natural - 9" w.c., Propane - 14" w.c.
- Pressure relief valve - capacity in excess of boiler input rating
- Integral induced draft fan
- Horizontal (Category III) or vertical (Category I) venting
- Air supply - natural aspiration
- Hot surface pilot ignition
- Slide-out burner tray
- Temperature/pressure gauge on outlet
- Temperature gauge on inlet
- Water header s- cast iron per ASME requirements
- Water tubes - pure copper with integral formed external fins
- Main burners - aluminized steel
- Pump relay standard
- Vent pressure safety switch
- Flame rollout safety switch
- Electrical - 115V/60Hz/1PH less than 12 Amps, 24 V transformer mounted and wired
-
20 Year Warranty
For more information on this product please view the Sheet(s) below: Laars Mini-Therm Brochure Laars Mini-Therm JVi,JVH Boiler Installation Manual Laars Mini-Therm JVi, JVH Parts List Laars Mini-Therm JVi, JVH 50-225 Boiler Submittal Data
|
Laars L0032900 Gas Orifice, LP
|
Laars L0032200 Gas Orifice, Natural
|
Laars L0050700 Gas Orifice, Natural
|
Laars R0384900 Fuse, 250V
|
Laars R0060500 Drain Valve, 1/2" NPT
|
Laars E0098500 Terminal Strip
|
Laars E0025900 Immersion Well (non-plated) - NEW REPLACEMENT SEE - RE2058300
|
Laars L0052500 Main Burner Tube
|
Laars L0056500 Burner Tube w/ Pilot Assembly Bracket
|
Laars E2103200 Roll Out Safety Switch w/ Manual Reset
|
Laars A2000600 Temperature Gauge
|
Laars E2074400 Transformer, 115/24V
|
Laars E2074504 Air Pressure Switch, High Altitude (5,000-10,000 FT)
|
Laars E2074501 Air Pressure Switch
|
Laars R2000504 JVH075 Conversion Kit: Natural Gas To LP, 0-5000 ft.
|
Laars R0061400 Pressure Relief Valve, 30 psi - OPN R51-182
|
Laars R0394902 Flue Outlet Replacement Kit for JVH075 - Nat/LP
|
Price: Replaced by: R2069600
Laars A2000200 Blower Motor, Induced Draft
|
Laars R0061300 Limit Switch
|
Laars RW2001800 Pilot Assembly, Hot Surface, Natural
|
Laars RW2001900 Pilot Burner, Hot Surface, LP
|
Laars D2000401 Vent Terminal, 6"
|
Laars D2004300 Vent Terminal, 4"
|
Laars R0384700 Hot Surface Natural Gas Valve
|
Laars R0384800 Gas Valve, Hot Surface, Liquefied Propane (LP)
|
Laars A2000400 Temperature/Pressure Gauge
|
Laars R2000605 JVH075 Conversion Kit: LP To Natural Gas, 0-2000 ft.
|
Product Reviews
|
|
|