Laars JVT 160 Mini-Therm Residential Gas-Fired Hydronic Boiler w. Pump
Item Number: 19450
Manufacturer Name: Laars Heating Systems Company
Manufacturer Part No: JVT160NDJS
|
|
Specifications:
- Input (BTU/h): 160,000
- Input (kW): 46.8
- Firing Mode: Configuration: Thermocouple/Continuous Burning Pilot
- Heat Capacity (BTU/h): 134,000
- Heat Capacity (kW): 39.3
- Net IBR (BTU/h): 116,900
- AFUE: 81
- Water Connection: 1-1/4"
- Gas Connection: 1/2"
- Minimum Clearances from Adjacent Construction:
- Left & Right Sides: 6"
- Front: 4"
- Flue: 6"
- Top: 23" (50-125), 36" (160 & 225)
Standard Features:
- Venting: built-in draft diverter
- Design certified/tested by CSA International
- Maximum working pressure - water 30 psi, ASME rated
- Hydrostatic test pressure at factory - 60 psi
- Material specifications as per Section IV, ASME Code
- Maximum gas supply pressure - Natural - 10.5" w.c., Propane - 13" w.c.
- Pressure relief valve - capacity in excess of boiler input rating
- Headers: cast iron per ASME requirements
- Tubes: pure copper with integral formed external fins
- Main burners: aluminized steel
- Air supply - natural aspiration
- Altitudes: 0-10,000 ft.
- Floor under boiler: when used on combustible floor, a special base must be supplied
- Two-stage combustion system and operating control (JVS sizes 100-225)
- Blocked vent safety switch (BVSS)
- Pump relay: standard
- Vent damper and wire harness
- Rollout safety switch
- Electrical - 115V/60Hz/1PH less than 12 Amps, 24 V transformer mounted and wired
-
20 Year Warranty
For more information on this product please view the Sheet(s) below: Laars Mini-Therm Brochure Laars Mini-Therm II JVS/JVT 50-225 Hydronic Boiler Installation Manual Laars Mini-Therm II JVT/JVS) Parts List Laars Mini-Therm II JVS/JVT 50-225 Boiler Submittal Data
|
Laars L0032900 Gas Orifice, LP
|
Laars L0055900 Burner Air Shutter
|
Laars L0050700 Gas Orifice, Natural
|
Laars E0098500 Terminal Strip
|
Laars E0025900 Immersion Well (non-plated) - NEW REPLACEMENT SEE - RE2058300
|
Laars L0052500 Main Burner Tube
|
Laars E2103200 Roll Out Safety Switch w/ Manual Reset
|
Laars L0056500 Burner Tube w/ Pilot Assembly Bracket
|
Laars W0036500 Thermocouple
|
Laars E0099101 Vent Damper Wire Harness
|
Laars 10562300 Anti-Rotation Bracket
|
Laars W0040902 Pilot Assembly, Natural Gas (NG), High Altitude
|
Laars R2000217 JVT160 Conversion Kit: LP To Natural Gas, 0-2000 ft.
|
Laars W0040901 Pilot Assembly, Liquefied Propane (LP)
|
|
Laars R0061400 Pressure Relief Valve, 30 psi - OPN R51-182
|
Laars R0021300 Transformer, 40 VA, 115/24V Kit
|
Laars W0040900 Pilot Assembly, Natural Gas (NG)
|
Laars R2000113 JVT160 Conversion Kit: Natural Gas To LP, 0-5000 ft.
|
Laars RE2058300 Well, Immersion, Nickel Plated
|
Laars R0061300 Limit Switch
|
Laars A0066500 Pump, PH 175-250, UP 26-96, UP 26-64
|
Laars R0011900 Ignition Control Assembly
|
Laars 10466703 Non-Combustible Base
|
Laars RE2071503 6" Vent Damper - OPN E2071503
|
Laars 20052603 Drafthood - (6")
|
|
Laars R0059100 Gas Valve, Natural - Honeywell VR8300H3131
|
Laars R0385000 Gas Valve Combo, Liquefied Propane (LP)
|
Laars R0402005 Heat Exchanger, 19" Wide
|