Laars EDP 175 Endurance Hydronic Boiler
Item Number: 11723
Manufacturer Name: Laars Heating Systems Company
Manufacturer Part No: EDP175
|
|
Specifications:
- Input (MBTU/h): 102.9-175.3
- Input (kW): 30.1-51.4
- Output (MBTU/h): 88.6-151.0
- Output (kW): 25.4-44.2
- AFUE%: 86.1
- Minimum Clearances from Combustible Materials:
- Back & Front: 1"
- Sides: 1"
- Top (Alcove Install): 1"
- Top (Closet Install): 22"
- Vent: Concentric, Direct: 0"
- Vent: Category IV: 3"
Features:
- Design certified and tested to ANSI standard Z21.13
- Designed and constructed in accordance with the ASME Boiler & Pressure Vessel Code, Sections II, IV, and IX
- Maximum working pressure - water 30 psi, ASME rated
- Hydrostatic test pressure at factory - 60 psi
- Minimum gas supply pressure - 4" w.c.
- Maximum gas supply pressure - 13" w.c.
- 85+% AFUE
- Sealed stainless steel combustion chamber
- Hot surface ignition
- Automatic burner modulation from 57% to full fire
- NOx levels less than 25 ppm
- Venting - Direct vent (sealed combustion with ducted combustion air in concentric vent) or Category III
- Design certified for installation directly on a combustible floor (except carpeting)
- One-inch clearance on all 4 sides
- Zero clearance from combustibles to the vent when concentric venting is used
- Electrical: 115V-60HZ-1PH less than 15 Amps with 24V transformer mounted and wired
- Outdoor reset with the addition of outdoor air sensor (limited temperature range available for EBP models)
- Control overrides outdoor reset when air sensor is faulty
- Easy-to-use viewing and programming menus
- 3-Character alphanumeric display of temperatures and fault codes
- Displays fault codes for supply sensor, return sensor, tank sensor (EBP only), outdoor air sensor, internal control, and lockout
- Displays 6temperatures: supply water, return water, tank water (EBP only), heatexchanger temperature rise, outdoor air temperature (when outdoor resetis used), and calculated setpoint (when outdoor reset is used)
- Controls LEDs indicated pump energized, attempt to ignite and gas valve energized
- Ignition control LEDs show faults for erroneous flame signal, internal error and lockout
- Low water temperature feature - attempts to run the pump when supply water temperature falls below 39°F
- Built-in circulating pump and by-pass loop
- Equipped with anti-condensing controls
- Pump exerciser to ensure pump remains free from corrosion
- Built-in safety limit
- Copper finned, cylindrical tube design heat exchanger brazed into ASME bronze headers
-
20 Year limited warranty
For more information on this product please view the Sheet(s) below: Laars Endurance EBP, EDP, EDN Installation Manual Laars Endurance Parts List Laars Endurance Questions And Answers Booklet
|
|
Laars 36-288 Control Panel Locking Standoff Clip
|
|
Laars 30-105 Gasket, 3/4" Nut
|
Laars 30-103 Gasket, 1" Nut
|
Laars 30-616 Line Voltage Fuse
|
Laars A2108100 Plastic Blower Cover
|
Laars 2400-437 5" Support Clamp
|
Laars 2400-528 Gasket, for Ignitor
|
Laars 2400-304 3" Spring Support
|
Laars 2400-282 Silicone Sealant
|
Laars 2400-281 Rubber Wall Flange, 5" Diameter
|
Laars 2400-349 2nd 90 Elbow, 5" Stainless Steel, Male x Female
|
Laars 2400-332 Vent Intake Pipe, 5" x 1' Stainless Steel
|
Laars 2400-514 Burner Gasket
|
Laars 2400-112 Pressure Relief Valve, 30 psi
|
Laars 2400-540 Gasket, Blower
|
Laars 2400-372 Alternate Vent Clamp
|
Laars 2400-356 5" Stainless Steel 45 Elbow, 5" Stainless Steel, Male x Female
|
Laars 2400-347 1st 90 Elbow, 5" Stainless Steel
|
Laars 2400-338 Vent Exhaust Pipe, 3" x 1' (SS AL29-4C)
|
Laars 2400-029 Thermostat & O Ring, for 1 1/4" Thermostatic Union
|
Laars 2400-146 Gas Orifice Kit, High Altitude
|
Laars 2400-446 Return Sensor
|
Laars 2400-568 Reset Switch
|
Laars 2400-280 Steel Wall Flange, 5" Diameter
|
Laars 2400-145 Gas Orifice Kit
|
Laars 2400-590 Gasket Kit
|
Laars 2400-411 3" x 24" Long Pipe Section
|
Laars 2400-438 Cone Flashing
|
Product Reviews
|
|
|